We offer testing services, based on the measuring method in accordance with Ministry of Internal Affairs and Communications Notification No. 628 dated October 10, 2001 of SAR -specific absorption rate in the human head- specified by law.
Applied to International Standard IEC 62209-2, the measuring method for SAR in human body except temporal part are regulated in Japan. We offer Body SAR test on the human body for the Radio equipment such as wireless LAN, mounted equipment and IoT equipment etc to be used near human body within 20 cm.
Also we are providing required test of radio equipment such as mobile phones those to be used near temporal within 20cm.
IEC 62209-1 | IEC 62209-2 | |
---|---|---|
Use position of the equipment | Wireless equipment to be used near temporal | Wireless equipment to be used within 20cm from human body |
Part of the body | Temporal | Head,Body ,Limbs except Temporal |
Examples of equipment | Mobile phones etc | Mobile phones, Tablet, PC and other wireless equipment |
Frequency | 300MHz – 3GHz → 300MHz – 6GHz | 30MHz – 6GHz |
Shape of phantom | Head | Flat shape |
Setting position | Cheek ,Inclined position | Specified position as actual use |
others | – | Basic part are same as 62209 ‒ 1 |
Guideline of Spatial -avarage absorption by MIC – Japanese only
*1 Source: Ministry of Internal Affairs and Communications website
Mobile phones, Smart phones, Mobile routers, Tablets, Laptops and so on.
Satelite phone
ORBCOMM, Thuraya, Inmarsat-GSPS type only-
Electric wave which are emitted from wireless equipment simultaneously and so on -WLAN, Digital wireless telephone, Personal handy phone are included.-
Less than 6GHz and more than 30MHz
Radio equipment which are estimated to be used at within 20cm from human body and also the average radio power are over the 20mW. Please ask us for more information.
The normal usage means that manufacture or seller define in the instruction manual of product.
We offer DFS test in accordance with Article 45 of Appendix to the Ministry of Internal Affairs and Communications Notification No. 88 in 2004.
Also we’re able to evaluate the DFS function in a shorter time by our unique DFS measurement system which adjust the detection rate in every radar pulse.
It is mandatory to verify that the radio frequency of specified equipment are conformed with the Technical Standards to obtain Technical Standard Conformity Certification and Authorization of the specified radio equipment by the Radio Law. We offer characteristic tests based on the testing method specified in the regulation of Ministry of Internal Affairs and Communications Notification No.88 in 2004.
It is mandatory to verify that the radio frequency of telecommunications terminal equipment are conformed with the Technical Standards to obtain Technical Standard Conformity Certification and Authorization by the Telecommunication Business Law.
We offer characteristic tests based on the testing method specified in the regulation of Ministry of Internal Affairs and Communications Notification No99 in 2004.